Home > Product > Accura3550
|
|
| |
|
| |
|
 |
Voltage, current, power, energy, PF, Hz
|
 |
DC
Voltage(current) Input, 1(2) channels |
 |
Digital Input/output, 4/1 channels |
 |
RS485,
Modbus RTU protocol |
|
|
|
 |
|
AC/DC Measurement Power Measurement
|
|
Accura
3550 is a high accuracy digital power meter dedicated to rectifier, suited to
power measurements and DC measurements. In rectifier, the existing customers
obtain dc voltage and current from analog inputs of RTU after converting
signals using separate tranducer. The signal conversion several times
deteriorates the overall data reliability, and causes the rising of costs. The
device simply replaces the existing RTU using Tranducer, solving the above two
problems.
|
| |
|
Accuracy, Power Quality
|
|
The
measuring accuracy is the most important criterion to evaluate the reliability
of energy management system. Actually low accuracy makes it hard for customers
to precisely manage energy, causing inequality of energy between incoming
feeder and sum of load sides. Accura 3550 makes ±0.2% high accuracy measurements for voltage and current, and conforms to IEC62053-22 class
0.5S for power and energy. This makes it possible to solve the problem with
energy inequality. Furthermore the device provides the information of power
qualities, such as voltage/current THD, harmonic analysis, and k factor.
|
| |
|
CE/UL Safety and Reliability
|
|
The structure-
framework, circuit, fire - of Accura 3550 conforms to safety standard,
CE[IEC61010], UL[UL61010-2, 2nd edition]. Particularly the device
provides pass-through busbar, allowing CT leads to be terminated on the device.
This eliminates any possible point of failure at the device. And optic
interface between meter and module essentially disturbs danger of the existing electrical
contacts.
|
| |
|
Communication[IrDA and RS485]
|
|
Accura
3550 provides two independent communication ports. One port provides RS485
communication which supports a variety of applications, such as energy management,
IBS, and SCADA. The Accura also has an optical IrDA port, allowing the device
to be set up and programmed using a PDA. Just point at the meter with
IrDA-equipped PDA, so customers can monitor measurements, harmonic graph,
vector diagram, demand trend, and oscilloscope.
|
|
|
|

|
|
|
Measurements
|
|
|

|
64 Sampling/Cycle True RMS
|
| |

|
IEC 62053-22 Class 0.5S
|
| |

|
50, 60Hz
|
| |

|
Phase voltage, line to line voltage, current |
| |

|
Power, energy, PF, Hz |
|
|

|
Fundamental component, True RMS of current
|
|
|

|
4 Quadrant Power
|
|
|

|
Demand, peak demand¢Ó
|
|
|

|
Maximum, minimum¢Ó
|
|
|
Power Quality
|
|
|

|
Voltage/current THD
|
|
|

|
Harmonic Analysis¢Ó
|
|
|

|
k factor¢Ó
|
|
|
|
|
|
|
|
|
|
|
|
|
|
IrDA Communication
|
|
|

|
Harmonic graph
|
|
|

|
Vector diagram
|
|
|

|
Demand trend
|
| |

|
Oscilloscope
|
| |

|
Module status/operation |
|
|
Communications
|
|
|

|
RS485 port[rear]
|
|
|
|
- Modbus RTU protocol
|
|
|
|
- Baudrate: 1,200 ~ 57,600bps
|
|
|

|
IrDA port[front]
|
|
|
|
|
|
|
|
|
|
Basic Module
|
|
|

|
DC module |
|
|
|
- DC Voltage Input 1 channel
|
| |
|
- DC Current Input 2 channels
|
| |
|
- Digital Input 4 channels
|
| |
|
- Digital Output 1 channel
|
|
|
Power Supply
|
|
|

|
DC 100 ~ 300V
|
|
|

|
AC 85 ~ 265V, 50/60Hz
|
| |

|
Burden 10VA |
|
|
|
|
|

|
|
|
Measurement dedicated to Rectifier
|
|
Rectifier panel guarantees reliability of
control power in energy system during the interruption of power. Accura 3550 is a high accuracy
digital power meter dedicated to rectifier, suited to power measurements, DC
measurements, and rectifier status.
|
|
|
|
True RMS Measurement robust to harmonics
|
|
Most
of energy environments consist of nonlinear loads, such as industrial load,
rectifier, power electronic device, electric furnace and etc. this causes fatal
distortion of voltage and current waveforms. Accura 3550 makes high accuracy
True RMS measurements for voltage and current distorted with harmonics.
|
|
|
|
Power Quality Analysis
|
|
Accura
3550 provides k factor, analysis of voltage and current up to 31st
harmonic, and realtime waveform of voltage and current.
|
|
|
|
Compatibility with Analog Meters
|
|
Accura
3550 mounts directly in ANSI C39.1[4¡± Round] or DIN 96. this is perfect for new
installations and for existing panels. In new installations, simply use
existing DIN or ANSI punches. For existing panels, pull out old analog meters
and fit the device in its cutout.
|
|
|
|
High Reliability Energy Management
|
|
The
most important point to evaluate the overall data reliability of energy
management is the accuracy of meters. Accura 3550 makes ±0.2% high accuracy measurements for voltage and current, and conforms to IEC62053-22 class
0.5S for power and energy. Energy management gives customers various services,
monitoring, cost curtailment, demand, energy planning, rectifier management and
etc.
|
|
|
|
|